IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home |
Release 8B Cumulative Fixes Last updated: Tuesday, 02-Dec-2014 14:57:29 EST IOF 8B fixes can be downloaded as a composite cumulative fix file in terse format. All IOF/TSO and IOF/CICS fixes are packaged together in a single file. The IOF maintenance dialog will "receive" and "apply" fixes from the cumulative fix file.
|
8B Cumulative Fix File Contents |
|||
---|---|---|---|
Product | FixNum Date |
Problem Description | Fixed in SpinLevel on Date |
IOF/TSO IOF/CICS |
T8B2354 C8B2354 19Dec2007 |
Improved version of the SETIOF command to display and update IOF Options. This fix supercedes U8B2333 and can be applied whether or not U8B2333 was previously applied |
These fixes have not been applied to a spin level
Release 8B is no longer the current IOF release so no additional spin levels for 8B will be built. It is recommended that you download and install the current IOF release in order to get all the maintenance pre-applied
|
IOF/TSO IOF/CICS |
U8B2300 16May2007 |
Add new hold reasons to the table of output group hold reasons. | |
IOF/TSO IOF/CICS |
U8B2299 16May2007 |
A CPU loop may result if a problem occurs trying to read a JES2 control block from spool in certain situations. | |
IOF/TSO |
T8B2298 16May2007 |
SNAPPAN command for
RUNNING jobs on the Job List Menu does not display the following fields:
SRVCLASS PERIOD WORKLOAD RESGRP SERVER QUIESCED |
|
IOF/TSO |
T8B2291 9May2007 |
The IOFCPUSR exec gives the wrong seconds value for IPL time. | |
IOF/TSO IOF/CICS |
U8B2289 9May2007 |
The OUTQUE clist may not sort properly. When taking a control break the clist may fail "invalid &SUBSTR range" | |
IOF/TSO IOF/CICS |
U8B2288 9Apr2007 |
Empty JCL sysouts are sporadically missing from the IOF Job Summary screen. This is due to IBM APAR OA10621/OA13292 which is applied to all z/OS V1R8 systems.. This fix removes all NULL datasets, unless SHOWNULL is used. See virtual help desk problem PC11 for more information. This fix replaces U8B2283 which is in error. This fix can be applied whether or not U8B2283 was previously applied. | |
IOF/TSO IOF/CICS |
U8B2284 4Apr2007 |
CN Option does not appear on Option menu when an ALLOW macro of the form "ALLOW d,u,COMMANDS,*" is the only macro present after applying fix 2272. | |
IOF/TSO IOF/CICS |
U8B2283 4Apr2007 |
This fix is in error and has been replaced by U8B2288. | |
IOF/TSO | T8B2287 4Apr2287 |
VIOF073C error when Option panel is missing from load module. Fix 2258 is in error. It specifies VIOF072E instead of VIOF073C as the message id to be added. | |
IOF/TSO IOF/CICS |
U8B2285 4Apr2007 |
The WLM environments and WLM resources screens display garbage in the SYSTEMS fields when no environments or resources have been defined. | |
IOF/TSO IOF/CICS |
U8B2274 4Apr2007 |
Add support for ThruPut Manager | |
IOF/TSO |
T8B2271 9Mar2007 |
Modify SLAMDEF to add an index entry for IEA822I messages | |
IOF/TSO IOF/CICS |
U8B2272 9Mar2007 |
Put the CN option on the IOF Option Menu when the user has authority to issue any MVS or JES2 command. | |
IOF/TSO IOF/CICS |
U8B2273 9Mar2007 |
The MAINT dialog always sets received and applied date in yyyy/mm/dd format, ignoring NLS specification for national date format. | |
IOF/TSO |
T8B2275 9Mar2007 |
Error messages are suppressed on exit from IOF when running in batch TSO. | |
IOF/TSO IOF/CICS |
U8B2276 9Mar2007 |
Refused error message received when attempting to SNAP LOG messages when ACTION messages are also displayed on screen and IBMSAF=YES is set in A60ACF option member. | |
IOF/TSO IOF/CICS |
U8B2277 9Mar2007 |
Jobs on DUPlicate hold not being marked such when all systems of a MAS are at z/OS V1.8 or higher. | |
IOF/TSO IOF/CICS |
U8B2278 9Mar2007 |
The "H" command on Job Detail panels displays the held group display instead of holding the current job on the detail panel. | |
IOF/TSO IOF/CICS |
U8B2279 9Mar2007 |
A "Command"/"Invalid command entered in primary input area" is received when the SETLOGRC command is issued from an MCS Console. | |
IOF/TSO |
T8B2281 9Mar2007 |
SLAMOPER issues an unnecessary TSIDEQ command when terminating | |
IOF/TSO IOF/CICS |
U8B2282 9Mar2007 |
DUMPCB command drops the high digit of the jobid for jobs with 6 digit jobids. | |
IOF/TSO IOF/CICS |
U8B2270 13Dec2006 |
The Job List Menu and Job Detail Display SYSID field for input jobs does not show the correct job affinity. | |
IOF/TSO | T8B2271 13Dec2006 |
Modify the SLAMDEF clist to add a log index entry for IEA822I messages | |
IOF/TSO IOF/CICS |
U8B2269 6Dec2006 |
The Enclave panel CPU field overflows after 27.7 hours of accumulated CPU time. |
2006341 |
IOF/TSO IOF/CICS |
U8B2268 6Dec2006 |
Retained action messages (ARMF) may not be displayed by the DR command, or by specifying ACTION ALL after MCS console restructure. | |
IOF/TSO |
T8B2267 6Dec2006 |
The ZAPCHK command may get error "IRX0041I Error running IOF$VZ1, line 91: Bad arithmetic conversion". | |
IOF/TSO IOF/CICS |
U8B2263 16Nov2006 |
Spun Null datasets are not being processed properly on the "IOF Job Summary" screen. | |
IOF/TSO IOF/CICS |
U8B2262 6Nov2006 |
PROCESS line command "T" (display threads) is REFUSED because FUNCTION THREADS is not defined in the B21ACESS option. Note that this fix will fail if FUNCTION THREADS is already defined. |
2006310
|
IOF/TSO IOF/CICS |
U8B2261 2Nov2006 |
MAINT command can get INVALID KEYWORD for STORCLASS during a RECEIVE, if the CFX file is placed on an SMS managed volume. | |
IOF/TSO IOF/CICS |
U8B2260 25Oct2006 |
HELP for the Health Checker Detail panel is missing. |
Optional Fixes
Click here for information of how to apply optional fixes |
Product | FixNum Date |
Option Description | Not applied to spin. |
IOF/TSO IOF/CICS |
U8B9001 |
The Kanji and Yiddish character sets define lower case characters to be unique characters. This fix modifies IOF to display all panel headers and HELP in upper case only. Browse data is not translated. | Optional |
IOF/TSO IOF/CICS |
U8B9004 |
AUTOCON setting is ON by default. This fix will set the default value to OFF so that users will not have to issue AUTOCON OFF. AUTOCON can be enabled by entering "AUTOCON ON". | Optional |
IOF/TSO IOF/CICS |
U8B9006 |
Force the IOF extended console name to equal the requestor's userid and default the console authority to INFO (unless overridden by security systems rules). | Optional |
IOF/TSO IOF/CICS |
T8B9007 C8B9007 |
A "Partial" error can occur because the number of items requested is too large to fit into the ECSA memory. This fix can be used to raise this maximum to whatever is deemed acceptable. | Optional |
IOF/TSO IOF/CICS |
U8B9008 |
The ACTION messages appearing at the bottom of the SYSLOG screen can contain messages from all systems of a SYSPLEX. This optional fix will filter messages such that only the messages originating from the current system will be displayed. | Optional |
IOF/TSO IOF/CICS |
U8B9042 |
Change the default allowable commands to be executed from 100 to 1024. | Optional |
IOF/TSO IOF/CICS |
U8B9051 |
Modify the ACTION command to display only outstanding WTORs. | Optional |
IOF/TSO IOF/CICS |
U8B9018 |
Force LOG=NONE on SAF calls performed for ALLOW macros with the ACF parmeter, when the A60ACF option members specifies RACF as the security system. | Optional |
IOF/TSO | T8B9028 |
Disable all internal exec processing. Revert to the IOF CLIST library as the source of all execs. | Optional |
IOF/TSO IOF/CICS |
U8B9015 |
Change the order of IBM defined SAF calls to check ALLOW and LIMIT macros before checking IBM defined classes. | Optional |
IOF/TSO IOF/CICS |
U8B9403 |
This optional fix allows IOF to make ACF=USER SAF calls during initialization. | Optional |
IOF/TSO IOF/CICS |
U8B9404 |
This optional fix permits IOF to make SAF calls with generic characters in the entity name. | Optional |
IOF/TSO IOF/CICS |
U8B9046 |
Define INVNULL as the default sort on the Job List Menu | Optional |
IOF/TSO IOF/CICS |
U8B9047 |
Define INVNULL as the default sort on the Output Group Display | Optional |
IOF/CICS | C8B9054 |
Suppress ending message if it is the normal "Processing Complete" message when CICS IOF transactions terminates. | Optional |
IOF/TSO | T8B9060 | Add the SENDMAIL and IOFSNDME commands to send jobs, output groups or sysout data sets via XMITIP email. This fix supersedes T8B9058 and can be applied whether or not T8B9058 was previously applied. | Optional |
IOF/TSO | T8B9059 | Add the XMITIP, XMITIPCU and XMITLDAP execs to the IOF CLIST library in order to support fix T8B9058 when XMITIP is not currently being run at a site. | Optional |
IOF Spin LevelsThe IOF distribution MPI file is periodically refreshed to a new spin level. A spin level consists of the previous level with additional maintenance applied. A spin level is identified by the julian date on which it was built, so the higher the number the more maintenance that has been applied. IOF fixes that are applied to a spin level are included in the IOF UPDATES data set. They are marked as "applied" by user "IOFSPIN". This allows the IOF maintenance dialog to accurately display the status of all applied maintenance. Use the IOF Maintenance Dialog to display the fix status or your system. To determine your IOF spin level:
|
Triangle Systems, Inc. PO Box 12752, Research Triangle
Park, NC 27709
IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home
[an error occurred while processing this directive]