IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home |
Release 8D Cumulative Fixes Last updated: Tuesday, 26-Mar-2019 15:48:07 EDT IOF 8D fixes can be downloaded as a composite cumulative fix file in terse format. All IOF/TSO and IOF/CICS fixes are packaged together in a single file. The IOF maintenance dialog will "receive" and "apply" fixes from the cumulative fix file.
|
8D Cumulative Fix File Contents
|
|||
---|---|---|---|
Product | FixNum Date |
Problem Description | Fixed in Spin Level on Date |
IOF/TSO | T8D2520 8Aug2012 |
Receiving "Undefined"/"The variable to be retrieved has not been defined" error when using the LOG command with LOGTYPE set to SYSLOG and INDEX=NO set in option member B30INDEX. |
These fixes have not been applied to an IOF spin level |
IOF/TSO | T8D2519 8Aug2012 |
No error message is given when a bad primary command is entered on the "IOF System Request Panel" displayed by the SR command. | |
IOF/TSO | T8D2516 8Aug2012 |
Add support to IOFREMC for dataset aliases and symbolic aliases. | |
IOF/TSO | T8D2507 8Aug2012 |
Change the KJ command to invoke IOF$ED1 instead of IOF$BF1. | |
IOF/TSO IOF/CICS |
U8D2513 8Aug2012 |
"Refused" error message when trying to access or alter a local printer that has 5 digits, as in PRT25412. | |
IOF/TSO IOF/CICS |
U8D2508 8Aug2012 |
"Too Long"/"MVS or JES2 command too long" error occurs when MVSCHAR=SLASH is set in B49CMPAT, and MVS/JES2 commands are issued on a customized 32xx screen that has 157 columns or more, such as a 3290 which is 62x160. NOTE: This does not occur from TSO READY and only occurs if you use the "/" command character. If you use MVSCMD it works. | |
IOF/TSO IOF/CICS |
U8D2505 8Aug2012 |
Possible S0C4-10 abend in IOF/CICS when exiting from a browse session of the JOB LOG dataset in a running JOB. Other abends are also possible. | |
IOF/TSO IOF/CICS |
U8D2504 8Aug2012 |
S0C4 and other abends are possible trying to display Output Groups using the "G"/"O" commands or the "H" command if there is any APPC transaction output selected. | |
IOF/TSO | T8D2503 24Feb2012 | The LOG command gets error message "Not Active" when OPERLOG is inactive, LOGTYPE is set to OPERACT and fix 2498 has been applied. LOG command should switch to SYSLOG in this case. | |
IOF/TSO IOF/CICS |
U8D2502 24Feb2012 | The GLOBSYS field of the Health Checker Display is blank when the GLOBAL field has a value of YES. | |
IOF/TSO IOF/CICS |
U8D2501 14Feb2012 | Total Line count displayed on the "IOF Output Group Display" just below the COMMAND line, is truncated on the left when it's value exceeds 999,999,999. | |
IOF/TSO IOF/CICS |
U8D2499 7Feb2012 | An overtyped field on any of the display menus is ignored if the panel is scrolled to the left or right. | |
IOF/TSO | T8D2487 15Dec2011 |
DUMP entries on "IOF DATA INDICES" menu are not sorted properly after ten or more SYSUDUMPs are in a SYSUDUMP dataset, and the BI command is used to construct an index for it. | |
IOF/TSO | T8D2491 15Dec2011 |
IOFSNDME does not select spun log and message data sets when JESDS=SPIN is in effect. | |
IOF/TSO | T8D2492 15Dec2011 |
The message text produced by IOFSNDME has extraneous spaces when some steps are not run. |
|
IOF/TSO | T8D2493 15Dec2011 |
Change the SEND command to allow overtyping of the PC file name with CSV or RTF. |
|
IOF/TSO | T8D2494 15Dec2011 |
Change SLAMPROC to detect a new time on multi-line messages and messges with a reply. |
|
IOF/TSO | T8D2497 15Dec2011 |
Fix T8D2485 is in error. This fix is a replacement fix. When LOGTYPE is set to OPERLOG and INDEX=YES is specified, modify the LOG command to continue when a log index is not found. |
|
IOF/TSO | T8D2498 15Dec2011 |
Add the OPERLOG command to browse Operlog without requiring an index. A single system operlog can be browsed. Multiple days' operlog can be browsed in a single OPERLOG session. |
|
IOF/TSO IOF/CICS |
U8D2490 15Dec2011 |
Record count in BROWSE session, wraps at 9,999,999 and begins counting again at 0, when CONDENSE ON is set. |
|
IOF/TSO IOF/CICS |
U8D2495 15Dec2011 |
"???" appear in STAT field when a JOB is prematurely ended due to Condition Codes and the STEP causing it had CC=0. |
|
IOF/TSO IOF/CICS |
U8D2496 15Dec2011 |
Values of "IOF_ERR__9" or "IOF_ERR__A" appare in the JOB RESULT field on z/OS V1.13 and above. |
|
IOF/TSO IOF/CICS |
U8D2477 27Apr2011 |
Refused access to "RES" or "JOB" command issued as a line command to an entry on the "IOF Scheduling Environment Display". | |
The two fixes below are required to run z/OS V1R13. These fixes can be applied before converting to V1R13. Note that the V1R12 fixes are also required. It is recommended that you install the latest MPI file when converting to V1R13. All available maintenance is applied to the latest MPI. |
These fixes 13 Sept 2011 This spin level runs with all versions of z/OS through V1R13 |
||
IOF/TSO IOF/CICS |
U8D2484 22Sept2011 |
Support is added for two z/OS V1.13 features. First is the usage of imbedded input datasets in an instream or catalogued procedure. Second is support for the usage of the SPIN parameter on SYSOUT datasets. | |
IOF/TSO IOF/CICS |
U8D2473 22Sept2011 |
This fix adds basic support for z/OS V1R13 | |
IOF/TSO |
T8D2479 27Apr2011 |
The JM command does not produce accurate output displays when running under z/OS 1.10 and later. | |
IOF/TSO IOF/CICS |
U8D2476 27Apr2011 |
For USERDest destinations, the string "LOCAL." is inserted between the JES2 nodename and the USERDest name, when the JES2 DESTDEF setting of SHOWUSER is set to WITHLOCAL. | |
IOF/TSO |
T8D2475 27Apr2011 |
"VIOFSC7C error" - "Panel not found" can occur when an entry is selected from the "Previous Days OPERLOG Selection Menu" panel. This panel is displayed when the "LOG OLD" command is issued and the LOGTYPE is set to OPERLOG. The error will occur only if IOF is started using a Rexx exec with LIBDEF commands for the IOF ISPF libraries. | |
IOF/TSO IOF/CICS |
U8D2474 27Apr2011 |
"<Screen Ovrflow>" error can occur on a 3270 model 2 when the SAVESORT option on Profile screen #1 is set to YES. This error can occur on the "IOF Job List Menu" and the "IOF System Monitor". | |
IOF/TSO IOF/CICS |
U8D2472 1Dec2010 |
Incorrect default address space selection on "IOF System Monitor" screen when parameters other than "ALL" are specified. | |
IOF/TSO IOF/CICS |
U8D2471 1Dec2010 |
Six asterisks periodically appear in the System SIO rate field when certain events occur, such as address starts, stops, or JOB step changes. | |
IOF/TSO |
T8D2470 1Dec2010 |
SLAMMEMO error "Cannot find first timestamped record" | |
The three fixes below are required to run with z/OS V1R12. These fixes may be applied before converting to V1R12. |
These fixes have
been applied to spin level This spin level runs with all
versions of z/OS through |
||
IOF/TSO IOF/CICS |
U8D2448 16Sept2010 |
Base level support for z/OS V1R12 so that IOF can be generated using the V1R12 JES2 and MVS libraries. | |
IOF/TSO IOF/CICS |
U8D2462 16Sept2010 |
Abend S0C1 trying to select a job that has come into a V1R12 system through an NJE device or through a Spool Offload device. | |
IOF/TSO IOF/CICS |
U8D2469 16Sept2010 |
"DUPLICATE DATASET ERROR" could appear inappropriately in the COMMENT column of the "IOF Job Summary" on a z/OS V1R12 system. | |
IOF/TSO IOF/CICS |
U8D2461 12Aug2010 |
The AUTO parameter of the SETCONS macro in B99MISC has no effect on Console Autostart. | |
IOF/TSO IOF/CICS |
U8D2463 12Aug2010 |
Possible abend S0C4 if attention key pressed while selecting a job from "IOF Job List Menu". | |
IOF/TSO IOF/CICS |
U8D2464 12Aug2010 |
Add SETPROG maintenance instructions for IOF modules that reside in LPA. | |
IOF/TSO |
T8D2460 12Aug2010 |
XMITIP will abend with system 001 when a job being sent via the SEND command or the IOFSNDME batch exec has a sysout data set with LRECL longer then 999. | |
IOF/TSO |
T8D2466 12Aug2010 |
Add a null PUSH statement to IOF$SE1 exec to eliminate an unnecessary ENTER. | |
IOF/TSO |
T8D2468 12Aug2010 |
Change IOF log date index names from YYDDD to YYYYMMDD. | |
IOF/TSO |
T8D2467 12Aug2010 |
After application of fix 2447, usage of the "<" command does not properly position in SYSLOG. | |
IOF/TSO IOF/CICS |
U8D2459 2July2010 |
Abend S0C4 can occur if in SYSLOG with ACTION messages visible on the screen and you try to use the EDIT command. | |
IOF/TSO IOF/CICS |
U8D2458 2July2010 |
Cannot scroll past entry 65534 on a "FIND ALL" screen. | |
IOF/TSO IOF/CICS |
U8D2457 2July2010 |
"Missing Parms" error with profile setting of MENUGLOB=NO, or "I Command in Browse" warning panel with profile setting of MENUGLOB=YES while trying to issue an "I SMF" MVS command in an Extended MVS Console. | |
IOF/TSO IOF/CICS |
U8D2456 2July2010 |
After application of fix 2452, garbage records
can can appear after "DD *" JCL cards in the reconstructed JCL from the EDIT command issued for a job on the "IOF Job List Menu". |
|
IOF/TSO IOF/CICS |
U8D2455 2July2010 |
Add some additional parameters to GRPOPTS for SDSF compatibility. | |
IOF/TSO IOF/CICS |
U8D2443 2July2010 |
Possible abend S0C4-4 browsing the LOG dataset of a running JOB, TSU, or STC. | |
IOF/TSO IOF/CICS |
U8D2451 7June2010 |
Sporadic S0C4 abends in APPC session trying to copy data back to client address space with TSICOPY statement. | |
IOF/TSO IOF/CICS |
U8D2452 7June2010 |
JES LOG dataset missing error messages and JES2 statistics when the JOB fails with JCL error prior to conversion. | |
IOF/TSO |
T8D2454 7June2010 |
"Missing Parms" error using LOCATE command in BROWSE session when the locate parameter starts with a period, as in "LOC .ABC". | |
IOF/TSO IOF/CICS |
U8D2449 11May2010 |
HELP for the Health Checker Option menu, OPTHCK, is missing. | |
IOF/TSO IOF/CICS |
U8D2450 11May2010 |
S0C4 abend or other possible symptoms trying to display an IOF Device List Display on z/OS V1.11 or higher. | |
IOF/TSO |
T8D2447 11May2010 |
The "<" command translates the submitted command to upper case. | |
IOF/TSO IOF/CICS |
U8D2442 5Apr2010 |
Error 3779 warning may terminate IOF clists or Rexx execs that select very large jobs. |
These fixes have been applied to IOF spin level
2010096 6 April 2010 |
IOF/TSO IOF/CICS |
U8D2445 5Apr2010 |
Sporadic abend S0C9 using IOF System Monitor. Additionally, support is added for 64 CPUs at z/OS V1.6 and 128 at z/OS V1.11 | |
IOF/TSO |
T8D2444 5Apr2010 |
The JAROPEN clist does not properly detect that DASD offload data set is requested based on a numeric value specified for the OFFTRKS variable after fix T8D2428 is applied. | |
IOF/TSO IOF/CICS |
U8D2431 22Feb2010 |
Abend S0C1/S0C4 can occur while browsing an open Job Log dataset. | |
IOF/TSO IOF/CICS |
U8D2432 22Feb2010 |
Abend S0C4 can occur while snapping Job's LOG dataset to SYSOUT from within Browse. | |
IOF/TSO IOF/CICS |
U8D2433 22Feb2010 |
The Job List Menu TIME field displays all blanks in the hours position for jobs that run between midnight and 1 am. | |
IOF/TSO IOF/CICS |
U8D2434 22Feb2010 |
CPU Loop trying to display "IOF Job Summary" for a job that has specified DUPLEX=YES in a system with "Output-Master", which is an obsolete product from the Xenos Group. | |
IOF/TSO IOF/CICS |
U8D2435 22Feb2010 |
The Job Summary SECLABEL field will contain x'00' for null values. TSICOPY of the SECLABEL field returns x'00' for null values. | |
IOF/TSO IOF/CICS |
U8D2436 22Feb2010 |
Incorrect line/page counts on device list for FSS printers when running under z/OS 1.11 JES2 or higher. | |
IOF/TSO IOF/CICS |
U8D2437 22Feb2010 |
Undefined keyword assembly error in OPTIONS and CONTROL assemblies of M13GEN, when PROPLIST macro specifies "Panel.DA.DynamiczAAPCols" or "Panel.DA.ShowTitleSIO". Incorrect parameters are generated with the GRPOPTS macro in B23ALLOW. | |
IOF/TSO IOF/CICS |
U8D2438 22Feb2010 |
"Partial" error in Spun log dataset for job in execution after applying fix U8D2431. | |
IOF/TSO |
T8D2439 22Feb2010 |
The PREST command may get "Invalid Mask" error when 8 character jobnames are entered. | |
IOF/TSO IOF/CICS |
U8D2440 22Feb2010 |
ASMA144E and ASMA143E errors in OPTIONS and CONTROL steps of M13GEN job because of invalid labels being generated during M86ISFCV job to convert ISFPARMS. M86ISFCV does not raise an error message. | |
IOF/TSO |
T8D2430 9Dec2009 |
After application of fix T8D2425, the characters "TCHD" may be prefixed to the MVS command being issued from the "LONG" command panel. | |
IOF/TSO IOF/CICS |
U8D2429 30Nov2009 |
Abend S0C4/S0C1 trying to access SYSLOG or OPERLOG when using the resident index and TRAPS(IGVINITFREEMAIN) is specified in a DIAGxx member of SYS1.PARMLIB. |
These fixes 2 December |
IOF/TSO |
T8D2428 30Nov2009 |
JAROPEN clist fails with return code 16 when the OFFTRKS parameter remains null. | |
IOF/TSO |
T8D2427 30Nov2009 |
The IOFSNDME exec may attempt to cancel the send work data set before JES2 has queued it. | |
IOF/TSO |
T8D2425 30Nov2009 |
The B99MISC option parameter LONGCMDC=TILDE is not honored. | |
IOF/TSO |
T8D2424 12Nov2009 |
The PREFIX command gets "invalid mask" error when multiplegeneric prefixes are specified. | |
IOF/TSO |
T8D2423 12Nov2009 |
Fix various problems with the SLAMDLTO exec to delete old OPERLOG indices and data. | |
IOF/TSO |
T8D2421 12Nov2009 |
The IOFSNDME exec FTP command does not FTP the job unless ZIP is specified. | |
IOF/TSO IOF/CICS |
U8D2422 12Nov2009 |
Abend S0C4 in certain circumstances where $$TRCALL$$ is used while invoking IOF. An example is in SLAMRUN. | |
IOF/TSO |
T8D2418 2Nov2009 |
The display of old OPERLOG logs does not contain the month. |
These fixes have been applied to IOF spin level 2009306 2 November 2009 |
IOF/TSO |
T8D2411 2Nov2009 |
Add the LOG repositioning feature to OPERLOG. | |
IOF/TSO |
T8D2417 2Nov2009 |
Allow browse of OPERLOG to use the resident operlog index. | |
IOF/TSO IOF/CICS |
U8D2419 2Nov2009 |
IOF HELP drops a character when displaying a long
highlighted variable that has to be split across lines. |
|
IOF/TSO IOF/CICS |
U8D2416 27Oct2009 |
Abend S0C4 when MG command is issued for a sysout dataset from TSO batch job. | |
IOF/TSO IOF/CICS |
U8D2415 27Oct2009 |
"IOF Snap Data Set Options" panel is displayed when SD command is issued from TSO Batch, but not in a clist or Rexx exec. | |
IOF/TSO IOF/CICS |
U8D2414 27Oct2009 |
Add support for IOFPARMS variable to identify IOF function startup parameters for diagnostic purposes. Note that this fix adds a significant debugging tool to IOF rather than fixing any known problem. | |
IOF/TSO |
T8D2413 27Oct2009 |
Add support for IOFPARMS variable to identify IOF function startup parameters for diagnostic purposes. | |
IOF/TSO IOF/CICS |
U8D2412 19OCT2009 |
The SORTDFLT parameter in the B99MISC member of the IOF OPTIONS library is not honored. | |
IOF/TSO IOF/CICS |
U8D2410 19OCT2009 |
Incorrect sort when sorting on TIMECOND field. The sort only sorts the TIME portion of the "DAY--TIME" field. | |
IOF/TSO |
T8D2327 6OCT2009 |
The LOG command fails when log indexing is specified but there is no SYSLOG index. | |
IOF/TSO |
T8D2409 6OCT2009 |
IOFSEND may loop when DATA=JESDS is specified as a parameter. |
Optional Fixes
|
Product | FixNum Date |
Option Description | Not applied to spin. |
IOF/TSO IOF/CICS |
U8D9001 |
The Kanji and Yiddish character sets define lower
case characters to be unique characters. This fix modifies IOF to display
all panel headers and HELP in upper case only. Browse data is not
translated. This fix has been replaced by the SETTRAN parameter in the |
Optional |
IOF/TSO IOF/CICS |
U8D9004 |
AUTOCON setting is ON by default. This fix will
set the default value to OFF so that users will not have to issue AUTOCON
OFF. AUTOCON can be enabled by entering "AUTOCON ON".
This fix has been replaced by the SETCONS parameter in the |
Optional |
IOF/TSO IOF/CICS |
U8D9006 |
Force the IOF extended console name to equal the
requestor's userid and default the console authority to INFO (unless
overridden by security systems rules).
This fix has been replaced by the SETCONS parameter in the |
Optional |
IOF/TSO IOF/CICS |
T8D9007 C8D9007 |
A "Partial" error can occur because the number of
items requested is too large to fit into the ECSA memory. This fix can
be used to raise this maximum to whatever is deemed acceptable.
This fix has been replaced by the SETCSA parm in the B99MISC |
Optional |
IOF/TSO IOF/CICS |
U8D9008 |
The ACTION messages appearing at the bottom of
the SYSLOG screen can contain messages from all systems of a SYSPLEX. This
optional fix will filter messages such that only the messages originating
from the current system will be displayed. This fix has been replaced by
the SETACTN parameter in the |
Optional |
IOF Spin LevelsThe IOF distribution MPI file is periodically refreshed to a new spin level. A spin level consists of the previous level with additional maintenance applied. A spin level is identified by the julian date on which it was built, so the higher the number the more maintenance that has been applied. IOF fixes that are applied to a spin level are included in the IOF UPDATES data set. They are marked as "applied" by user "IOFSPIN". This allows the IOF maintenance dialog to accurately display the status of all applied maintenance. Use the IOF Maintenance Dialog to display the fix status or your system. To determine your IOF spin level:
|
Triangle Systems, Inc. PO Box 12752, Research Triangle
Park, NC 27709
IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home