IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home
|
Release 7J Cumulative Fixes Last updated: Wednesday, 21-Jul-2010 13:50:32 EDT IOF 7J fixes can be downloaded as a composite cumulative fix file in terse format. All IOF/TSO and IOF/CICS fixes are packaged together in a single file. The IOF maintenance dialog will "receive" and "apply" fixes from the cumulative fix file.
|
7J Cumulative Fix File Contents |
|||
---|---|---|---|
Product | FixNum Date |
Problem Description | Fixed in SpinLevel on Date |
IOF/TSO IOF/CICS |
U7J2228 2MAY2006 |
Correct problems with STEP display on the IOF Job Summary for started tasks that have explicit JOB statements. This fix supersedes fix 2224 and fixes an abend S0C1 caused by 2224. It can be applied whether or not U8A2224 was previously applied. | These fixes have not been applied to any spin level |
IOF/TSO | T7J2227 2MAY2006 |
The JARDEL command can get SUBSTR error 932 when there are certain catalog discrepancies. | |
IOF/TSO IOF/CICS |
U7J2224 24APR2006 |
This fix has been superseded by U8A2228. | |
IOF/TSO | T7J2219 24APR2006 |
VIOF320A message is missing from ISPMLIB | |
IOF/TSO | T7J2088 24APR2006 |
Add the EDIT JOB function to the Output Group Display. | |
IOF/TSO | T7J2215 31MAR2006 |
The SR command terminates with a panel error when running on a non-standard screen size between 80 and 132 characters. | |
IOF/TSO |
T7J2170 21MAR2006 |
. When a SYSID value is saved in a user's profile, the "L O" command to browse OPERLOG attempts to browse an operlog for that system only. This fix supercedes T7J2169 and can be applied whether or not T7J2169 was previously applied | |
IOF/TSO | T7J2172 21MAR2006 |
SLAMMEMR clist gets return code 852 and error message IKJ56545I Character data item used numerically in SYSTSPRT. | |
IOF/TSO | T7J2186 21MAR2006 |
Abend S30A-24 when terminating an ISPF edit session of certain SYSOUT datasets. | |
IOF/TSO IOF/CICS |
U7J2164 21MAR2006 |
Duplicate SYSOUT datasets can be displayed on the IOF Job Summary in certain circumstances. | |
IOF/TSO IOF/CICS |
U7J2167 21MAR2006 |
A CPU Loop can occur attempting to do a "FIND xxx PREV" from the bottom of SYSLOG when using the "L" command to access it. | |
IOF/TSO IOF/CICS |
U7J2168 21MAR2006 |
Correct Message Suppression on various SAF calls when IBMSAF=YES is specified. | |
IOF/TSO IOF/CICS |
U7J2171 21MAR2006 |
When in BROWSE with DISPLAY CC in effect, FIND x'8B' does not find the 8B machine carriage control character. | |
IOF/TSO IOF/CICS |
U7J2173 21MAR2006 |
The system monitor task SIO count field overflows when the count exceeds 8 digits. | |
IOF/TSO IOF/CICS |
U7J2177 21MAR2006 |
Several data set detail panels truncate the low order digit of the RECORDS field. | |
IOF/TSO IOF/CICS |
U7J2185 21MAR2006 |
Abend S0C9 trying to bring up IOF Monitor screen due to wildly large SIO rate for an address space. This fix forces IOF to look for possible S0C9 and bypass rate calculation. | |
IOF/TSO IOF/CICS |
U7J2191 21MAR2006 |
Browsing a spun sysout data set from a running job is not possible under certain circumstances. | |
IOF/TSO IOF/CICS |
U7J2192 21MAR2006 |
"Partial" error when browsing the LOG or MESSAGES dataset of a job that is using "SPUN" logs. This "Partial" error can also occur if the job terminates while browsing the LOG or MESSAGES dataset. | |
IOF/TSO IOF/CICS |
U7J2196 21MAR2006 |
Correct a spelling error in DVAR display. | |
IOF/TSO IOF/CICS |
U7J2210 21MAR2006 |
SIORate shows max value of 999.9 after applying fix U7J2179. This corrects to allow a max value of 9999.9. | |
IOF/TSO IOF/CICS |
U7J2211 21MAR2006 |
Change the MAINT dialog to give return code 8 instead of return code 12 on PREREQ, NREQ and certain other errors to avoid line mode error messages being displayed. | |
IOF/TSO IOF/CICS |
U7J2167 8Aug2005 |
A CPU loop can result from issuing the "FIND PREV" command. Note that this fix can solve several problems with the "FIND PREV" command. | 2005217 5Aug2005
|
IOF/TSO | T7J2166 8Aug2005 |
The edit job temporary data set has lrecl 32756 when editing a job under z/OS 1.7. Edit and submit work OK, but the COMP utility to compare to the original data set fails. | |
IOF/TSO | T7J2165 8Aug2005 |
Add the error number to the JAROFFLD command error messages. | |
IOF/TSO IOF/CICS |
U7J2164 8Aug2005 |
Duplicate SYSOUT datasets can be displayed on the IOF Job Summary in certain circumstances. | |
IOF/TSO IOF/CICS |
U7J2160 23Jun2005 |
The "?" line command for sysout data sets not in a group has a spelling error in the description of the COMP command. | |
IOF/TSO IOF/CICS |
U7J2161 23Jun2005 |
Add support to IOF for z/OS V1R7. IOF will continue to generate properly for earlier versions of OS/390 and z/OS after this fix is applied. | |
IOF/TSO |
T7J2162 23Jun2005 |
Add a PAUSE parm to the IOFLISTG and OUTQUE clists to allow controlling the speed that job or group cancel commands can be issued. | |
IOF/TSO IOF/CICS |
U7J2163 23Jun2005 |
Specifying SORT with no parms on the Job List Menu produces unpredictable results if an initial sort was specified on the IOF Option Menu. | |
IOF/TSO IOF/CICS |
U7J2159 17May2005 |
Browse may interpret sysout carriage control incorrectly when PDBRECFM indicates no carriage control, but some records have carriage control. | 2005138 18May2005 |
IOF/TSO IOF/CICS |
U7J2158 17May2005 |
Duplicate SYSOUT can still appear in certain circumstances with U7J2155 applied. | |
IOF/TSO IOF/CICS |
U7J2156 17May2005 |
A CPU Loop can occur attempting to do a "FIND xxx PREV" from the bottom of SYSLOG when using the "L" command to access it. | |
IOF/TSO | T7J2157 17May2005 |
Add the SNAP parm to the LRDT command. | |
IOF/TSO IOF/CICS |
U7J2155 28Mar2005 |
Duplicate sysout data sets can be displayed on the IOF Job Summary in certain circumstances. | |
IOF/TSO IOF/CICS |
U7J2154 28Mar2005 |
A CPU Loop can occur under certain circumstances when selecting a job from the "IOF Job List Menu". | |
IOF/TSO IOF/CICS |
U7J2153 28Mar2005 |
When browsing the OPERLOG, pressing HELP results in error message "requested HELP not found". | |
IOF/TSO IOF/CICS |
U7J2152 4Mar2005 |
The QT command suggests using the "RC" command to retrieve the highest return code for all jobs on the Job List Menu. The Status field now contains this information for non-zero return codes. Update QT to reflect this change. | |
IOF/TSO IOF/CICS |
U7J2151 4Mar2005 |
The spool percent display on the MAS panel is too high for very small SPOOL systems because the BLOB tracks are shown as allocated tracks. Note that this fix requires z/OS 1.4 or later to be effective. There are no changes for earlier systems. | |
IOF/TSO IOF/CICS |
U7J2150 4Mar2005 |
Incorrect data on SS line command screen on second or subsequent usage for same dataset without exiting from JOB Summary screen. | |
IOF/TSO IOF/CICS |
U7J2149 4Mar2005 |
Incorrect data on SS line command screen after applying fix U7J2140. | |
IOF/TSO IOF/CICS |
U7J2148 4Mar2005 |
The ISFAUTH.DEST.** violation message are not suppressed when theuser is a Destination Operator or has READ access to the profile ISFOPER.DEST.jesx. | |
IOF/TSO IOF/CICS |
U7J2147 4Mar2005 |
Modify the JOB CONTROL attribute to set a job type of
CONVERT when a job is being converted. This allows a LIMIT macro on the
CONTROL attribute to distinguish jobs being converted. The LIMIT macro below in
B23ALLOW will prevent any user from canceling a job while it is in conversion.
LIMCNVT LIMIT 1,0,JOBS,CONTROL,'*.*.*.CONVERT.CANCEL',ID=* |
|
IOF/TSO IOF/CICS |
U7J2146 4Mar2005 |
HELP on the Job Summary Panel shows incorrect syntax for snapping part of a sysout data set. | |
IOF/TSO IOF/CICS |
U7J2145 4Mar2005 |
The "R" line command on the Job Summary Panel takes the default class from the Snap Defaults Profile Panel (P.2) even when a class is specified in the User Profile Panel (P.1). | |
IOF/TSO IOF/CICS |
U7J2144 11Jan2005 |
Authorization message for RACROUTE call to ISFOPER.DEST.JES2 and ISFOPER.ANYDEST.JES2 is not suppressed. | 2005 011 11Jan2005 |
IOF/TSO IOF/CICS |
U7J2143 11Jan2005 |
HELP on the Job List Menu, Option 2, SORT option gets "screen Ovrflow" error (HELP panel overflows physical screen). | |
IOF/TSO | T7J2142 10Jan2005 |
Add the DUMPCB line command to the Output Group Display | |
IOF/TSO IOF/CICS |
U7J2141 6Jan2005 |
After application of PTF UA15627 (APAR UA15627), the JESCTL step of the M13GEN job gets error ASMA068S length error for symbol S35DL. | |
IOF/TSO IOF/CICS |
U7J2140 6Jan2005 |
The SS line command on the IOF Job Summary sets the OUTNAME field to the value of the DDNAME of the selected data set, which causes the allocation to fail because the specified DDNAME is not defined. | |
IOF/TSO IOF/CICS |
U7J2139 6Jan2005 |
The "?" line on the Job Summary Panel, then "C" from the detailpanel can result in abend 0C1. | |
IOF/TSO IOF/CICS |
U7J2138 6Jan2005 |
If the first step of a multi-step job creates a dynamically allocated sysout data set and the job is selected with IOF while the first step is still running, the dynamically allocated sysou may appear in the data set list of the IOF Job Summary as having been created by the last step of the job. | |
IOF/TSO | T7J2137 6Jan2005 |
.When multiple SUBMIT line commands are entered, only the first job is submitted. | |
IOF/TSO | T7J2136 6Jan2005 |
Error "invalid SORT specified" results from specifying the SORT parm on the OUTQUE command, and there are no jobs matching the specified selection criteria. | |
IOF/TSO | T7J2134 22Oct2004 |
The SLAMDLTO clist will not delete 7J formatted OPERLOG index data sets. | |
IOF/TSO IOF/CICS |
U7J2132 22Oct2004 |
The ALLOC field displays the number of track groups allocated to a job modulo 32767. This problem was originally fixed by U7J2124, but U7J2124 causes M13GEN errors when generating for OS/390 or Z/OS 1.1 systems. This fix can be applied whether or not U7J2124 is applied. | |
IOF/TSO IOF/CICS |
U7J2130 22Oct2004 |
Possible S0C4 abend in SLAMMEMO when more than output is being snapped. The problem is the progress indicator when more than one item is being snapped into the same output dataset from an IOF Job List Menu or IOF Output Group Display. | |
IOF/TSO |
T7J2116 29Sept2004 |
When the JES2 command character is a period (.), the "<" command may not work properly. | 2004 279 5Oct2004 |
IOF/TSO |
T7J2117 29Sept2004 |
The MVS (abbrev #) command does not display an error message when a command is refused. When the JES2 command character is period (.), JES2 commands can not be entered. | |
IOF/TSO |
T7J2118 29Sept2004 |
The RC command gets a "bad keyword specified" message and does not set the return codes. | |
IOF/TSO |
T7J2119 29Sept2004 |
When FULL is specified as a parm to the IOFSNPMN exec, error message "COMMAND EXTEND NOT FOUND" is displayed and the extended data is not captured. The FULL parm on the IOFSNPGR exec does not capture extended fields. | |
IOF/TSO IOF/CICS |
U7J2120 29Sept2004 |
Default SORT order for jobs in "Input Jobs" section is class withing position instead of position within class. | |
IOF/TSO IOF/CICS |
U7J2121 29Sept2004 |
SNAP to a CC=M dataset can result in a garbage record being written to the output dataset. | |
IOF/TSO IOF/CICS |
U7J2123 29Sept2004 |
Abend S0C4 can occur when a LIMIT 0,0 macro is used in B23ALLOW to exclude certain jobs from the IOF Job List Menu. | |
IOF/TSO IOF/CICS |
U7J2124 29Sept2004 |
The ALLOC field displays the number of track groups allocated to a job modulo 32767. | |
IOF/TSO IOF/CICS |
U7J2125 29Sept2004 |
Abend S0C4 can occur during SNAPCLOS after snapping entire job to a RECFM=xxM disk dataset from "IOF Job List Menu". | |
IOF/TSO IOF/CICS |
U7J2126 29Sept2004 |
The SORT assist panel states that the specified sort will be saved in the user's profile. SORTTEMP displays the same panel but does not update the profile. Change the HELP description to state that SORTTEMP sets a temporary sort. | |
IOF/TSO |
T7J2127 29Sept2004 |
The minimum abbreviation of the NOZERO parm to the RC command is "NO" instead of "N" as documented in HELP. The NOZERO parm does not function properly. | |
IOF/TSO IOF/CICS |
U7J2128 29Sept2004 |
System abend S0C4 will occassionally be produced when cancelling jobs or groups when cancel confirmation is on. | |
IOF/TSO IOF/CICS |
U7J2129 29Sept2004 |
The format of output jobs on the Job List Menu shows a blank screen if an alternate view has been defined. |
Optional Fixes
Click here for information of how to apply optional fixes |
Product | FixNum Date |
Option Description | Not applied to spin. |
IOF/TSO IOF/CICS |
U7J9001 9Jul2004 |
The Kanji and Yiddish character sets define lower case characters to be unique characters. This fix modifies IOF to display all panel headers and HELP in upper case only. Browse data is not translated. | Optional |
IOF/TSO IOF/CICS |
U7J9004 9Jul2004 |
AUTOCON setting is ON by default. This fix will set the default value to OFF so that users will not have to issue AUTOCON OFF. AUTOCON can be enabled by entering "AUTOCON ON". | Optional |
IOF/TSO IOF/CICS |
U7J9005 9Jul2004 |
Disable automatic swapin of a running task when an open dataset is selected for browse. When this fix is applied, it is not possible to browse data in buffers of swapped out running jobs. | Optional |
IOF/TSO IOF/CICS |
U7J9006 9Jul2004 |
Force the IOF extended console name to equal the requestor's userid and default the console authority to INFO (unless overridden by security systems rules). | Optional |
IOF/TSO IOF/CICS |
T7J9007 C7J9007 9Jul2004 |
A "Partial" error can occur because the number of items requested is too large to fit into the ECSA memory. This fix can be used to raise this maximum to whatever is deemed acceptable. | Optional |
IOF/TSO IOF/CICS |
U7J9008 9Jul2004 |
The ACTION messages appearing at the bottom of the SYSLOG screen can contain messages from all systems of a SYSPLEX. This optional fix will filter messages such that only the messages originating from the current system will be displayed. | Optional |
IOF/TSO | T7J9009 9Jul2004 |
When the ISPF RETURN command is issued from an application that was initiated via an IOF command that specified NEWAPPL, control returns to the ISPF option menu, bypassing IOF. This optional fix causes control to return to IOF; but disables the ISPF JUMP (=) feature. The IOF EDIT command, and the TEXTREF command interfacing to QUICKREF are two examples of linking to a NEWAPPL. | Optional |
IOF/TSO IOF/CICS |
U7J9015 9Jul2004 |
This optional fix changes the order of IBM defined SAF calls to check ALLOW and LIMIT macros before checking IBM defined classes. | Optional |
IOF/TSO IOF/CICS |
U7J9018 9Jul2004 |
Force LOG=NONE on SAF calls performed for ALLOW macros with the ACF parmeter, when the A60ACF option members specifies RACF as the security system. | Optional |
IOF/TSO IOF/CICS |
U7J9019 9Jul2004 |
Change IOF to force LOGGING for TSS SAF calls. | Optional |
IOF/TSO IOF/CICS |
U7J9021 9Jul2004 |
An optional fix to prevent DEVID conversion when the active device is a PSEUDO device. | Optional |
IOF/TSO | T7J9022 9Jul2004 |
This is an OPTIONAL fix. Add an INITCMD field to the OPTUS3 option panel. The INITCMD is the name of a clist or Rexx exec to be executed on entry to the Job List Menu or Output Group Display. Also add a sample INITCMD in the form of the IOFSORTX clist. | Optional |
IOF/TSO IOF/CICS |
U7J9032 9Jul2004 |
This is an OPTIONAL fix. This optional fix increases the number of JOBNAME masks that can be specified in the USSCOPE/USSCLST parm from 32 to 96. | Optional |
IOF/TSO IOF/CICS |
U7J9033 9Jul2004 |
This is an OPTIONAL fix. IOF will not display a spun dataset on "IOF Job Summary" if it has already printed or has been purged. This optional fix provides a default value that will allow all datasets to always be displayed. Additionally, IOF does not query status of the NULLSYSO variable if defined as an option variable, only as a profile or session. | Optional |
IOF/TSO IOF/CICS |
U7J9035 9Jul2004 |
This is an OPTIONAL fix. Optional fix to always raise "Data Set Empty" message for Select, Print, Snap, or Alloc, when the dataset is a null SPUN sysout | Optional |
IOF/TSO IOF/CICS |
U7J9041 9Jul2004 |
This is an OPTIONAL fix. Change IOF to allow SMF logging, ACF2 messages, and the violation count to be honored. | Optional |
IOF/TSO IOF/CICS |
U7J9042 24Jun2004 |
This is an OPTIONAL fix. Change the default allowable commands to be executed from 100 to 1024. | Optional |
IOF/TSO IOF/CICS |
U7J9043 29Sep2004 |
This is an OPTIONAL fix. Add support for XPAF attribute fields | Optional |
IOF/TSO IOF/CICS |
U7J9046 29Sep2004 |
This is an OPTIONAL fix. Define INVNULL as the default sort on the Job List Menu | Optional |
IOF/TSO IOF/CICS |
U7J9047 29Sep2004 |
This is an OPTIONAL fix. Define INVNULL as the default sort on the Output Group Display | Optional |
IOF/TSO |
T7J9048 29Sep2004 |
This is an OPTIONAL fix. Add an error routine to the IOF7J exec. | Optional |
IOF/TSO IOF/CICS |
U7J9051 | Modify the ACTION command to display only outstanding WTORs. | Optional |
IOF/TSO IOF/CICS |
U7J9052 | The EDIT JOB command may cause abend 913 when IBMSAF=NO is specified in the A60ACF option, and the JESSPOOL SAF class is enabled. | Optional |
IOF/TSO | T7J9053 | The EDIT data set command may cause abend 913 when IBMSAF=NO is specified in the A60ACF option, and the JESSPOOL SAF class is enabled. | Optional |
IOF Spin LevelsThe IOF distribution MPI file is periodically refreshed to a new spin level. A spin level consists of the previous level with additional maintenance applied. A spin level is identified by the julian date on which it was built, so the higher the number the more maintenance that has been applied. IOF fixes that are applied to a spin level are included in the IOF UPDATES data set. They are marked as "applied" by user "IOFSPIN". This allows the IOF maintenance dialog to accurately display the status of all applied maintenance. Use the IOF Maintenance Dialog to display the fix status or your system. To determine your IOF spin level:
|
Triangle Systems, Inc. PO Box 12752, Research Triangle
Park, NC 27709
IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home
[an error occurred while processing this directive]