IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home |
Release 7G Cumulative Fixes Last updated: Monday, 26-Jul-2004 15:43:01 EDT IOF 7G fixes can be downloaded as a composite cumulative fix filein terse format. All IOF/TSO and IOF/CICS fixes are packagedtogether in a single file. The IOF maintenance dialog will"receive" and "apply" fixes from the cumulative fix file.
|
7G Cumulative Fix File Contents | |||
---|---|---|---|
Product | FixNum
Date | Problem Description | Fixed in
SpinLevel on Date |
IOF/TSO | T7G2062
10Apr2003 |
Excessive CPU time is used by IOF when a job with a very large number of datasets is selected. |
These fixes are not applied to any 7G spin level |
IOF/TSO | T7G2061
10Apr2003 |
The SLAMRUN CLIST specifies the UNIT parm on the SAVEINDX instruction even when the index data set already exists. This can cause errors when the index data set has been moved to a different volume serial. | |
IOF/TSO | T7G2057
10Apr2003 |
When the LOGTYPE is set to OPERACT, the first "L" command in each IOF session does not detect that OPERLOG is active, so displays SYSLOG instead. | |
IOF/TSO | T7G2056
10Apr2003 |
The SLAMMEMO and SLAMMEMR clists do not pass the &INIT parm when invoking the SLAMPROC clist. | |
IOF/TSO
IOF/CICS |
U7G2046
10Dec2002 |
Add the "ARM" description to the STATUS field on the IOF Job List Menu to indicate that the job is registered with the Automatic Restart Manager (ARM). | |
IOF/TSO
IOF/CICS |
U7G2050
13Nov2002 |
This fix supercedes fixes
U7G2039, U7G2032 and U7G2018. It can be applied
whether or not the superceded fixes were previously applied.
Selecting specific failed jobs or STC with imbedded procedures can cause system abend 0C1 in the STEPSCAN module (042D) with the superceded fix(es) applied. | |
IOF/TSO | T7G2049
13Nov2002 |
Modify the IOF7G exec so that it will pass IOF parms properly when invoked from an ISPF Option Panel. | |
IOF/TSO
IOF/CICS |
U7G2045
23Sept2002 |
This fix supercedes fixes U7G2040
and U7G2037. It can be applied whether or not the superceded fixes were previously
applied.
Incorrect access to Initiator, Line, or Offload device when A60ACF specifies IBMSAF=YES and there is no SDSF profile defined to control the access. The security violation message for SDSF profile ISFOPER.SYSTEM is suppressed and will not appear on terminal or in SYSLOG. | |
IOF/TSO | T7G2043
18Sept2002 |
The JAROFFLD SPOOLPC parm is not processed properly and may produce totally random results. | |
IOF/TSO
IOF/CICS |
U7G2044
18Sept2002 |
When running under OS/390 2.8 or a later release JES2, remove the single FORMS limitation for remote printers. | |
IOF/TSO
IOF/CICS |
U7G2040
13Sept2002 |
This fix has been superceded by
U7G2045.
The security violation message for SDSF profile ISFOPER.SYSTEM is suppressed and will not appear on terminal or in SYSLOG. | |
IOF/TSO
IOF/CICS |
U7G2041
13Sept2002 |
An S0C4 abend will occur if an IOF Initialization trace is attempted when the operating system is running in 64 bit mode. | |
IOF/TSO | T7G2042
13Sept2002 |
The print check command (PC) will not check remote printers if both local and remote printers are set to the same destination. | |
IOF/TSO
IOF/CICS |
U7G2037
30July2002 |
This fix has been superceded by
U7G2045.
Incorrect access to Initiator, Line, or Offload device when A60ACF specifies IBMSAF=YES and there is no SDSF profile defined to control the access. IOF should try and use B23ALLOW but does not. | 2002 210
29July2002 |
IOF/TSO
IOF/CICS |
U7G2039
18July2002 |
This fix is superdeded by fix U7G2050
The "Not cataloged 2" message is not displayed in the IOF Job Summary Panel after fix U7G2032 (of U7G2018) has been applied. This fix should be applied whether or not U7G2032 or U7G2018 has previously been applied. It superceeds both previous fixes.
| |
IOF/TSO
IOF/CICS |
U7G2038
18July2002 |
The Job Summary DEST field header is shifted one character to the right. | |
IOF/TSO | T7G2036
28June2002 |
Document the COMP line command on the IOF Job Summary Panel HELP. | |
IOF/TSO | T7G2035
22May2002 |
When a TSO command is specified as a parm on the IOF TS command, the TSO command is not issued. | |
IOF/TSO
IOF/CICS |
U7G2017
21May2002 |
The Job List Menu and Output Group Field STATUS field may be blank if a step fails to run even if another step of the job has a non-zero return code. | |
IOF/TSO | T7G2024
21May2002 |
The "SB" Job Summary Command requires ISPF, and will not function from the IOF server. Give an error message if these conditions are not met. | |
IOF/TSO | T7G2034
21May2002 |
The EDIT primary command issued from IOF BROWSE will edit only 99999 lines by default. | |
IOF/TSO
IOF/CICS |
U7G2032
30Apr2002 |
This fix is superceeded by U7G2039.
When a job contains JCL after the NULL JCL statement, and fix U7G2018 has been applied, the IOF Job Summary Panel displays the jobs input data sets in error. This can prevent the EDIT JOB line command from rebuilding an input job correctly. This fix should be installed if U7G2018 was previously installed, but can be installed without U7G2018. Forked Unix address spaces generate multiple IEF142I messages in the system messages data set, causing IOF to incorrectly assign return codes to incorrect steps. With this fix applied, a separate line is shown in the IOF Job Summary for each forked address space. | 2002 133
13May2002 |
IOF/TSO
IOF/CICS |
U7G2025
24Apr2002 |
The REAL field on the "IOF System Monitor" panel only holds five digits even after application of fix 1824. Note fix 1824 is a co-requisite of this fix and must be applied. | |
IOF/TSO
IOF/CICS |
U7G2026
24Apr2002 |
A "NOMATCH" or empty "IOF Job List Menu" results when the HELDOUT select clause is used to try and bring up a list of jobs that have any held output. | |
IOF/TSO
IOF/CICS |
U7G2028
24Apr2002 |
An incorrect message appears in TRACE for an ALLOW macro when an IFALSO clause is present. The message indicating the start of the IFALSO processing says it is for a LIMIT macro even though the IFALSO clause is actually on an ALLOW macro. | |
IOF/TSO | T7G2027
24Apr2002 |
Modify the SLAMRUN and SLAMOPER clists to disable most indices when excessive indexing is detected. Excessive indexing is specified by the new CONDRATE parm on SLAMRUN and SLAMOPER. The default CONDRATE for SLAMRUN is 100 events per 2.5 minutes. The default CONDRATE for SLAMOPER is 200 events per 2.5 minutes. These defaults can be overidden by specifying a different CONDRATE value. | |
IOF/TSO | T7G2029
24Apr2002 |
Cursor positioning after pressing the "END" command to cancel the TS popup window is erratic. | |
IOF/TSO | T7G2030
24Apr2002 |
This fix updates the changes made by fix T7G2027 to prevent the NEWDAY condition from triggering excessive indexing. Note that T7G2027 must be applied prior to applying this fix. | |
IOF/TSO
IOF/CICS |
U7G2031
24Apr2002 |
Correct fix U7G2023 to cause instructions to be printed if superzap terminates with RC 4. Note that this fix can be applied whether or not U7G2023 has been applied. | |
IOF/TSO
IOF/CICS |
U7G2023
20Mar2002 |
The MAINT command does not display instructions for which jobs to run when a superzap fix gets return code 4 because of IDRDATA overflow. | 2002 099
9Apr2002 |
IOF/TSO
IOF/CICS |
U7G2013
20Mar2002 |
A job with a user abend in the STAT field of the "IOF Job List Menu", will never show any overriding status such as JOB hold. | |
IOF/TSO | T7G2014
20Mar2002 |
Job HOLD is not properly checked when the PC (print check) command is issued for a data set on the Job Summary Panel. | |
IOF/TSO | T7G2015
20Mar2002 |
The COMPARE command will not function if the MSGCLASS of the TSO session specifies a DUMMY sysout class. Compare may not function or may be very slow if a large value for the GROUP MINPAUS value is specified. | |
IOF/TSO | T7G2016
20Mar2002 |
The carriage control is not preserved by the IOF EDIT SAVE function. | |
IOF/TSO | U7G2018
20Mar2002 |
This fix is superceeded by U7G2039.
Forked Unix address spaces generate multiple IEF142I messages in the system messages data set, causing IOF to incorrectly assign return codes to incorrect steps. | |
IOF/TSO
IOF/CICS |
U7G2020
20Mar2002 |
Invalid characters can appear in the JOBID on the "IOF Job Summary" screen when an OMVS address space is selected from a "IOF System Monitor" screen built using the "APPC R" command. | |
IOF/TSO
IOF/CICS |
U7G2021
20Mar2002 |
IOF browse may get error 2301 (Data set empty) when spool block has no valid records even though it chains to a valid block. JES2 APAR OW53453 describes a problem where JES2 writes null blocks in the Job Console Log which causes the problem. | |
IOF/TSO | T7G1200
31Jan2002 |
When the default log type is OPERLOG, the "L OLD" command does not display old OPERLOG index data sets at the beginning of the year. | 2002 031
31Jan2002 |
IOF/TSO | T7G1201
31Jan2002 |
Change the SLAMPROC clist to save the index before exiting when error conditions are encountered. | |
IOF/TSO | T7G1202
31Jan2002 |
The "L" command enables display of NULL sysout data sets. | |
IOF/TSO | T7G1544
31Jan2002 |
The JAR UPLOAD command submits jobs on TYPRUN=HOLD when the JARSERVR is not being used. | |
IOF/TSO | T7G1545
31Jan2002 |
An IOF server APPC session may not detect that the client session has terminated, especially when the EVERY command is being run on the server session. | |
IOF/TSO | T7G1825
31Jan2002 |
Modify the JARCLOSE clist to delete the directory and offload data sets when no jobs were actually offloaded. | |
IOF/TSO | T7G1826
31Jan2002 |
An abend 0C4 may result from entering the TSO command with no parms. | |
IOF/TSO | T7G2009
31Jan2002 |
Abend 0C4 results from entering the TS command from IOF HELP, and then entering a null TSO command. | |
IOF/TSO | T7G2010
31Jan2002 |
Several minor problems with replies to WTORs via the SR command are corrected. Non quoted replies are translated to upper case. | |
IOF/TSO
IOF/CICS |
U7G1543
31Jan2002 |
Abend 0C4 in IOF browse caused by bad spool data. This fix adds checks for the bad data and gives an I/O error when bad data is encountered. | |
IOF/TSO | T7G2008
17Dec2001 |
The JOBID field on panels VIOFUPL2 and VIOFUPL3 is only 6 characters long, but should be 7 characters. | 2001 351
17Dec2001 |
IOF/TSO | T7G2007
12Dec2001 |
The TS command with no parms gives "numeric" (numeric value expected) error when IOF is running from TSO READY. | |
IOF/TSO | T7G2006
12Dec2001 |
The 7G version SLAMMEMO, SLAMARCH, SLAMWTR and IOFWTR clists will not run with older versions of IOF. Add checks to insure that the proper IOF version is being used. | |
IOF/TSO | T7G1199
12Dec2001 |
Specification of the VOLSER parm of the SLAMOPER clist causes IKJ56712I invalid keyword error. | |
IOF/TSO
IOF/CICS |
U7G1824
12Dec2001 |
The REAL field on the System Monitor panel is limited to 5 digits. Expand REAL to 6 digits. | |
IOF/TSO
IOF/CICS |
U7G1541
12Dec2001 |
Refresh the IOF Job Summary Panel after the INTTEXT command is entered to correct a problem when EXCLUDE is entered immediately after the INTTEXT command. | |
IOF/TSO | T7G1539
12Dec2001 |
The DF command on the Output Group Display gets an invalid statement error when a group has an IP destination. | |
IOF/TSO
IOF/CICS |
U7G1823
12Dec2001 |
Add an enque test to the VFIX maintenance dialog (MAINT command) to insure that an IOF data set member to be updated is not in use. | |
IOF/TSO | T7G2005
2Nov2001 |
Add a description of the COMPARE facility to the NEW7G help. | 2001 306
2Nov2001
Initial
All these
|
IOF/TSO
IOF/CICS |
U7G2004
2Nov2001 |
Abend S0C1 entering "IOF System Monitor" on z/OS V1.2 or higher. | |
IOF/TSO | T7G2003
2Nov2001 |
Add the COMP line command to the Job Summary Panel to support comparing sysout data sets. | |
IOF/TSO
IOF/CICS |
U7G2002
2Nov2001 |
The fix name is not displayed properly on WFIXU error VFIX panel. | |
IOF/TSO | T7G2001
2Nov2001 |
Define a HELP panel for the SR panels | |
Optional Fixes
Click here for information of how to apply optional fixes | |||
Product | FixNum
Date | Option Description | Not
applied to spin. |
IOF/TSO
IOF/CICS |
U7G9001
2Nov2001 |
The Kanji and Yiddish character sets define lower case characters to be unique characters. This fix modifies IOF to display all panel headers and HELP in upper case only. Browse data is not translated. | Optional |
IOF/TSO
IOF/CICS |
U7G9002
2Nov2001 |
Cause IOF to prefix unquoted data set names with both the user's prefix and userid unless they are the same, in which case only the prefix will be used. | Optional |
IOF/TSO
IOF/CICS |
U7G9003
2Nov2001 |
The default screen size for IOF in TSO Batch is 60 lines. This optional patch changes the screen size to 255. | Optional |
IOF/TSO
IOF/CICS |
U7G9004
2Nov2001 |
AUTOCON setting is ON by default. This fix will set the default value to OFF so that users will not have to issue AUTOCON OFF. AUTOCON can be enabled by entering "AUTOCON ON". | Optional |
IOF/TSO
IOF/CICS |
U7G9005
2Nov2001 |
Disable automatic swapin of a running task when an open dataset is selected for browse. When this fix is applied, it is not possible to browse data in buffers of swapped out running jobs. | Optional |
IOF/TSO
IOF/CICS |
U7G9006
2Nov2001 |
Force the IOF extended console name to equal the requestor's userid and default the console authority to INFO (unless overridden by security systems rules). | Optional |
IOF/TSO
IOF/CICS |
T7G9007
C7G9007 2Nov2001 |
A "Partial" error can occur because the number of items requested is too large to fit into the ECSA memory. This fix can be used to raise this maximum to whatever is deemed acceptable. | Optional |
IOF/TSO
IOF/CICS |
U7G9008
2Nov2001 |
The ACTION messages appearing at the bottom of the SYSLOG screen can contain messages from all systems of a SYSPLEX. This optional fix will filter messages such that only the messages originating from the current system will be displayed. | Optional |
IOF/TSO | T7G9009
2Nov2001 |
When the ISPF RETURN command is issued from an application that was initiated via an IOF command that specified NEWAPPL, control returns to the ISPF option menu, bypassing IOF. This optional fix causes control to return to IOF; but disables the ISPF JUMP (=) feature. The IOF EDIT command, and the TEXTREF command interfacing to QUICKREF are two examples of linking to a NEWAPPL. | Optional |
IOF/TSO
IOF/CICS |
U7G9011
31Jan2002 |
Ignore the test for $ACTIVATE and attempt to display the highest return code in the STATUS field. | Optional |
IOF/TSO
IOF/CICS |
U7G9013
2May2002 |
This optional fix adds Enclave CPU time to the "CPU" field on
the "IOF Job List Menu" and to the "CPU" field on the "IOF System Monitor" screen.
NOTE: This is a temporary solution and the final implementation in the next release of IOF could be done differently. | Optional |
IOF/TSO | T7G9014
9July2002 |
This optional fix has been replaced by optional fix T7G9017. This fix is now obsolete. | Optional |
IOF/TSO
IOF/CICS |
U7G9015
28June2002 |
This optional fix changes the order of IBM defined SAF calls to check ALLOW and LIMIT macros before checking IBM defined classes. | Optional |
IOF/TSO
IOF/CICS |
U7G9016
28June2002 |
This optional fix provides INTERIM IOF support for z/OS
V1.4. This fix will disable HELD dataset support, preventing "Cancel", "Release", or
dataset modification functions.
IOF release 7H provides full support for z/OS 1.4. Release 7H provides HELD data set support. | Optional |
IOF/TSO | T7G9017
9July2002 |
This fix replaces fix T7G9014. It can be applied whether of
not T7G9017 has been applied.
The PREFIX command will store invalid prefix characters in the profile. The user can not get into IOF with the invalid profile characters stored. This optional fix modifies the PREFIX command to process an intermediate "*" wildcard character by changing "*" to multiple prefixes with "*" replaced by multiple "+" characters. For example PREFIX AB*CD* is translated to "AB+CD* AB++CD* AB+++CD*". Invalid prefix characters are detected and not allowed. | Optional |
IOF/TSO
IOF/CICS |
U7G9018
13Sept2002 |
Force LOG=NONE on SAF calls performed for ALLOW macros with the ACF parmeter, when the A60ACF option members specifies RACF as the security system. | Optional |
IOF/TSO
IOF/CICS |
U7G9019
13Sept2002 |
Change IOF to force LOGGING for TSS SAF calls. | Optional |
IOF/TSO IOF/CICS |
U7G9021
10Dec2002 |
An optional fix to prevent DEVID conversion when the active device is a PSEUDO device. | Optional |
IOF/TSO | T7G9022
10Dec2002 |
This is an OPTIONAL fix. Add an INITCMD field to the OPTUS3 option panel. The INITCMD is the name of a clist or Rexx exec to be executed on entry to the Job List Menu or Output Group Display. Also add a sample INITCMD in the form of the IOFSORTX clist. | Optional |
IOF/TSO
IOF/CICS |
U7G9025
10Apr2002 |
This is an OPTIONAL fix. Change the way IOF highligts a JOB on the Output Queue from having the today's day portion of the Julian date to having a JOE create time within the last 24 hours. | Optional |
IOF Spin LevelsThe IOF distribution MPI file is periodically refreshed to a newspin level. A spin level consists of the previous level withadditional maintenance applied. A spin level is identified bythe julian date on which it was built, so the higher the numberthe more maintenance that has been applied. IOF fixes that are applied to a spin level are includedin the IOF UPDATES data set. They are marked as "applied" byuser "IOFSPIN". This allows the IOF maintenance dialog toaccurately display the status of all applied maintenance. Use the IOF Maintenance Dialog to display the fix status or your system. To determine your IOF spin level:
|
Triangle Systems, Inc. PO Box 12752, Research TrianglePark, NC
27709
IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home