IOFTech    Maintenance   Release8G       Newsletters    Doc    FAQ    Contact    Home

Common Technical Question
Question R02
Previous Next
Description The IOF Output Group Display has a HOLDRSN field that describes why a group in being HELD by the SYSTEM. What are the meanings of the hold reason abbreviations?
 
Answer The IOF HOLDRSN field is based on field JOEHSRSN in the JES2 JOE control block. IOF converts JOEHSRSN from a number to an abbreviation. The reasons are documented by IBM MACRO IAZOHLD which can be found in SYS1.MACLIB. An expanded version of the hold reasons can be found in IOF SOURCE data set member EASYJOE at label "SYSRESON".

--JOEHSRSN-----HOLDRSN------Description--------------------
         1     FSI-SWB      FSI RELDS UNPRINT SWB ERROR
         2     FSI-FSA      FSI RELDS UNPRINT FSA
         3     SAF          SAF CALL FAILED IN HASPPRPU
         4     HASPNET      TRANSMISSION FAILED IN HASPNET
         5     NJE HOP      NJE HOP COUNT EXCEDED
         6     API          HELD BY SYSOUT API
        51     OFFLOAD      OFFLOAD WITH HOLD
        52     HASPPRPU     PROGRAM CHECK IN HASPPRPU
        53     USEREXIT     PROGRAM CHECK IN USER EXIT
        54     SWBTUREQ     PROGRAM CHECK IN SWBTUREQ
        55     SJFREQ       PROGRAM CHECK IN SJFREQ
       101     BAD NODE     NETWORK NODE INVALID
       105     FSI GET      FSI GET DATASET PROCESSOR ERROR
       106     FSI RELD     FSI RELDS UNPRINTABLE ABEND
       110     NO WORK      NO WORK AVAILABLE
       111     JDSPOINT     JDSPOINT ERROR OSDPOINT RTN
       115     PSO HELD     PROCESS SYSOUT DATA SET HELD
       120     JDS CKPT     JDSPOINT ERROR IN CHKPT RTN
       121     CHK STT      CHKPT ASSIGN IN STT FAILED
       122     CHK JSTA     CHKPT ASSIGN IN JOBSTAT FAILED
       123     CHK DSTA     CHKPT ASSIGN IN DSTAT FAILED
       140     PDQJBSEL     FSS PIPELINE ERROR - PDQJBSEL
       141     PDQDSSEL     FSS PIPELINE ERROR - PDQDSSEL
       142     PDQWOSWR     FSS PIPELINE ERROR - PDQWOSWR
       143     PDQWOSRD     FSS PIPELINE ERROR - PDQWESRD
       144     MISS REF     MISSING OUTPUT REFERENCE
 

 
More Help Click here to EMAIL a problem report to IOF Technical Support for additional assistance.

 

Previous Next

Triangle Systems, Inc. PO Box 12752, Research Triangle Park, NC 27709
(919) 544-0090

IOFTech    Maintenance   Release8G       Newsletters    Doc    FAQ    Contact    Home

Thursday, 22-Jul-2021 11:38:19 EDT
 

@@