IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home |
Release 7F Cumulative Fixes Last updated: Monday, 26-Jul-2004 15:40:53 EDT IOF 7F fixes can be downloaded as a composite cumulative fix file in terse format. All IOF/TSO and IOF/CICS fixes are packaged together in a single file. Instructions for Downloading and Applying Cumulative Fixes 7F Cumulative Fix File Contents Download the IOF 7F cumulative fix file Description of IOF Spin Levels
Technical Problems and Questions
|
7F Cumulative Fix File Contents | |||
---|---|---|---|
Product | FixNum
Date |
Problem Description | Fixed in SpinLevel on Date |
IOF/TSO | T7F2024
1May2002 |
The "SB" Job Summary Command requires ISPF, and will not function from the IOF server. Give an error message if these conditions are not met. |
These fixes are not applied to any 7F spin level.
Download |
IOF/TSO IOF/CICS |
U7F2025
1May2002 |
The REAL field on the "IOF System Monitor" panel only holds five digits even after application of fix 1824. Note fix 1824 is a co-requisite of this fix and must be applied. | |
IOF/TSO  | T7F2027
1May2002 |
Modify the SLAMRUN and SLAMOPER clists to disable most indices when excessive indexing is detected. Note that fix T7F2030 should also be applied after this fix is applied. | |
IOF/TSO  | T7F2030
1May2002 |
This fix updates the changes made by fix T7F2027 to prevent the NEWDAY condition from triggering excessive indexing. Fix T7F2030 should be applied before this fix is applied. | |
IOF/TSO IOF/CICS |
U7F2013
20Mar2002 |
A job with a user abend in the STAT field of the "IOF Job List Menu", will never show any overriding status such as JOB hold. | |
IOF/TSO | T7F2014
20Mar2002 |
Job HOLD is not properly checked when the PC (print check) command is issued for a data set on the Job Summary Panel. | |
IOF/TSO | T7F2016
20Mar2002 |
The carriage control is not preserved by the IOF EDIT SAVE function. | |
IOF/TSO IOF/CICS |
U7F2019
20Mar2002 |
The Job List Menu I/O count field displays only 7 digits when option B12XAIO is set to COUNT. | |
IOF/TSO IOF/CICS |
U7F2021
20Mar2002 |
IOF browse may get error 2301 (Data set empty) when a spool block has no valid records even though it chains to a valid block. JES2 APAR OW53453 describes a problem where JES2 writes null blocks in the Job Console Log which causes the problem. | |
IOF/TSO | T7F1194
31Jan2002 |
Long MVS commands entered on the VIOFCMDS panel are translated to upper case. This does not allow UNIX commands to be entered. | |
IOF/TSO | T7F1201
31Jan2002 |
Change the SLAMPROC clist to save the index before exiting when error conditions are encountered. | |
IOF/TSO | T7F1202
31Jan2002 |
The "L" command enables display of NULL sysout data sets. | |
IOF/TSO | T7F1545
31Jan2002 |
An IOF server APPC session may not detect that the client session has terminated, especially when the EVERY command is being run on the server session. | |
IOF/TSO | T7F1826
31Jan2002 |
An abend 0C4 may result from entering the TSO command with no parms. | |
IOF/TSO
IOF/CICS |
U7F1824
12Dec2001 |
The REAL field on the System Monitor panel is limited to 5 digits. Change REAL to display 6 digits. | |
IOF/TSO | T7F1199
12Dec2001 |
Specification of the VOLSER parm of the SLAMOPER clist causes IKJ56712I invalid keyword error. | |
IOF/TSO
IOF/CICS |
U7F1541
12Dec2001 |
Refresh the IOF Job Summary Panel after the INTTEXT command is entered to correct a problem when EXCLUDE is entered immediately after the INTTEXT command. | |
IOF/TSO
IOF/CICS |
U7F1197
12Dec2001 |
The I/O field on the "IOF Job List Menu" begins to decrement when the address space I/O connect time exceeds 76 hours 21 minutes. | |
IOF/TSO | T7F2003
6Nov2001 |
Add the COMP line command to the Job Summary Panel to support comparing sysout data sets. | |
IOF/TSO | T7F1539
6Nov2001 |
The DF command on the Output Group Display gets an invalid statement error when a group has an IP destination. | |
IOF/TSO
IOF/CICS |
U7F1198
25Oct2001 |
Change the IOF translate table so that all characters X'40' and higher are displayed. | |
IOF/TSO
IOF/CICS |
U7F1195
28Sep2001 |
An inadvertant SVCDUMP can be generated by IOF due to an S0C1 abend in the JES2 channel end appendage. IOF continues normally. | |
IOF/TSO
IOF/CICS |
U7F1196
10Sep2001 |
Correct IOF to display the Euro character (X'9F')
This fix is superceeded by U7F1198. | |
IOF/TSO
IOF/CICS |
U7F1819
20Jun2001 |
The ACTION field on the Output Group Display will display an action for mutiple groups when the OUTGRP field is 5 characters or larger. Positioning on the Output Group Display may be also be erratic. If you have jobs with more than 9999 output groups, or if you name output groups with names longer than 4 characters, this fix should be applied. |
2001 172 21Jun2001 |
IOF/TSO
IOF/CICS |
U7F1817
20Jun2001 |
Change the maintenance dialog RECEIVE process to CALL the unpack program, GIMUNPCK, instead of invoking it as a TSO command. | |
IOF/TSO | T7F1538
20Jun2001 |
Modify the PC command to check the remote status. Also give an error when PC is issued for a dataset not assigned to a group. | |
IOF/TSO | T7F1190
20Jun2001 |
The JARDJOIN clist invokes IEBGENER as a TSO command, which is not supported under OS/390 2.10. JAROPEN and JARCLOSE are also modified to release unused DASDI space. Note that if retention period is specified, the operator must reply to permit space release. | |
IOF/TSO
IOF/CICS |
U7F1189
7Jun2001 |
The asterisk (*) character is not allowed in the FORMS field on local or remote printers. | |
IOF/TSO
IOF/CICS |
U7F1816
7Jun2001 |
Add the CNSCROLL command. CNSCROLL ON causes the IOF extended console to scroll any new command to the top of the screen. CNSCROLL OFF disables console scrolling. CNSCROLL status is saved in the user's profile. | |
IOF/TSO
IOF/CICS |
U7F1814
22May2001 |
An abend S0C4 can occur if the B64ACFCK option is used to control access to output groups. |
2001 142 22May2001 |
IOF/TSO
IOF/CICS |
U7F1813
22May2001 |
An S282-30 abend can occur if ACF=GLOBAL or ACF=USER is specified in an ALLOW macro, and IBMSAF=YES is specified in the A60ACF option. | |
IOF/TSO
IOF/CICS |
U7F1811
22May2001 |
The browse job line command on the Job List Menu reads the whole messages data set, even when the NODATA command is in effect. | |
IOF/TSO
IOF/CICS |
U7F1808
22May2001 |
The A60ACF option member documents the IBMRACF parm in error. The parm should be IBMACF. This fix corrects the comments. | |
IOF/TSO | T7F1815
22May2001 |
Change the IOFADDC exec to allow specification of multiple dsnames in the DSNAME parm when enclosed within parenthesis. | |
IOF/TSO | T7F1810
22May2001 |
Change the IOFREMC exec to allow specification of multiple dsnames in the DSNAME parm. | |
IOF/TSO | T7F1188
24Apr2001 |
Period is not allowed as the subsystem command character on the LONG command panel, VIOFCMDS. | |
IOF/TSO | T7F1537
24Apr2001 |
The SLAMMEMO task can get error 977, "Invalid Menu # Specified" on slow or very busy systems. | |
IOF/TSO | T7F1807
17Apr2001 |
The PC (print check) line command for a job may not accurately describe why a job will not print. |
2001 108 18Apr2001 |
IOF/TSO
IOF/CICS |
U7F1806
17Apr2001 |
The COMMAND area is not cleared after a RFIND command detects a "not found" condition. | |
IOF/TSO
IOF/CICS |
U7F1805
17Apr2001 |
Change the VFIX dialog to verify the cumulative fix file checksum and free the file after processing is complete. | |
IOF/TSO
IOF/CICS |
U7F1804
23Mar2001 |
Error message "Job is Gone" is displayed when selecting an output group from the Output Group Display when the JOBID for the job is 32768 or higher. This fix supercedes U7F1803 and should be applied whether or not U7F1803 was previously applied. |
2001 088 29Mar2001 |
IOF/TSO
IOF/CICS |
U7F1536
23Mar2001 |
An incorrect error message, "OFFSETYF", is raised when overtyping certain fields for NON-HELD datasets on the Job Summary Panel. | |
IOF/TSO
IOF/CICS |
U7F1802
22Mar2001 |
Change the maintenance dialog (VFIX) to save IOF data set names in the shared variable pool instead of the ISPF profile. | |
IOF/TSO
IOF/CICS |
U7F1187
20Mar2001 |
Abend 0C4 on the "L" command when operating in z/OS 64 bit mode. |
2001 081 22Mar2001 |
IOF/TSO
IOF/CICS |
U7F1801
20Mar2001 |
Change the default cumulative fixes DSNAME to prefix.IOF7FFIX.CFX. | |
IOF Spin LevelsThe IOF distribution MPI file is periodically refreshed to a new spin level. A spin level consists of the previous level with additional maintenance applied. A spin level is identified by the julian date on which it was built, so the higher the number the more maintenance that has been applied. The latest release 7F spin level is "2001 172" which was built on June 21, 2001. IOF fixes that are applied to a spin level are included in the IOF UPDATES data set. They are marked as "applied" by user "IOFSPIN". This allows the IOF maintenance dialog to accurately display the status of all applied maintenance. Use the IOF Maintenance Dialog to display the fix status or your system. To determine your IOF spin level:
|
Triangle Systems, Inc. PO Box 12752, Research Triangle
Park, NC 27709
IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home
[an error occurred while processing this directive]