SYSEXEC read error when running the audit MPI exec.
|
Information |
When PROFILE MSGID is in effect the error messages below will be
displayed on the terminal. If PROFILE NOMSGID is in effect, the
IRX message number will not be displayed.
IRX0562E Abnormal completion of the READ Data Management macro.
|
Background |
The audit MPI procedure extracts and concatenates a data set to
the TSO users SYSEXEC file. The MPI file is has fixed length
records of length 80 (RECFM=FB,LRECL=80). If the record format
of the system SYSEXEC files is variable (VB) instead of fixed
(FB), the read error will result and the Rexx exec will not be
executed.
|
SOLUTION |
You must FREE the SYSEXEC file before attempting to execute the
audit MPI. From the COMMAND line, enter:
TSO FREE FILE(SYSEXEC) Then get into IOF and run the MPI exec.
When you are finished running the audit MPI procedure, you may want
to logoff TSO and logon again to re-establish your normal SYSEXEC
environment.
|