Description The I/O field on the Job List Menu for running jobs is always blank.
 
BACKGROUND The I/O field on the Running Jobs Section of the Job List Menu displays either the I/O channel connect time, or the I/O count. IOF OPTION data set member B12XAIO is used to select the connect or count.

Emulated systems such as the MP3000, or Flex systems do not properly calculate channel connect time.


 

SOLUTION If the computer is an emulated system (MP3000, Flex, etc) then edit the B12XAIO member and change the last statement to be:

SETXAIO     COUNT

Save the updated member. Run the M18NEWOP job from the IOF INSTALL library. When complete, refresh LLA.
 

More Help Click here to EMAIL a problem report to IOF Technical Support for additional assistance.

 