IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home
|
IOF Problem Resolution Problem B01 |
---|---|
Previous | Next |
Description |
System abend Fxx. SVC xx not found.
|
Background |
Abend Fxx means that SVC number xx (in hex) is not found. Convert
xx to decimal to get the decimal SVC number in question.
That SVC is not installed correctly.
IOF requires either an ESR or an SVC in order to gain required authorization. The customer selects the ESR or SVC in member A10AUTH of the IOF OPTIONS library. Instructions for installing the ESR or SVC are provided in the comments in A10AUTH, and in Section 2 of the IOF Installation Guide which can be downloaded from this web page. When IOF abends with code Fxx, it usually means that the IOF SVC was not installed correctly.
|
Solution |
The SVC specified in option A10AUTH is not properly installed.
"AUTH SVC=nnn" was specified in the A10AUTH option.
Check to insure that the SVCPARM statement in the IEASVCxx member of 'SYS1.PARMLIB' is properly specified as described in Section 2 of the IOF Installation Guide which can be downloaded from this web page. Check to insure that the IGC00XXX member of the IOF LOAD library is properly renamed and copied to the system LPA library as described in Section 2 of the IOF Installation Guide.
|
Additional check |
Check to insure that another module with the same SVC name does
not exist in LPA, perhaps in an earlier LPA concatenation.
|
Note |
A system IPL is required in order for a member of an LPA library
to be accessable by the system unless this site has one of the
products that dynamically update LPA libraries.
|
Note |
When the primary solutions to a problem do not change the symptoms,
perhaps the wrong IOF load module(s) are being executed. The IOF and
IOFSPF modules will load from a STEPLIB or ISPLLIB. The IOF/CICS
IOFCIC load module (invoked by transaction code IOF) runs from a
library in the CICS DFHRPL concatenation. The other four IOF load
modules must be resident in a system LINKLIST or LPA library. See
the January/February 1999 Newsletter for
a better discussion of IOF load modules.
IOF/TSO provides the IOFWHERE Rexx exec in the IOF CLIST library to assist in determining the specific load modules and libraries being used. To use IOFWHERE, make sure that the IOF CLIST library is concatenated to the SYSPROC file for the TSO session. From ISPF Option 6, or from TSO READY, enter:
IOFWHEREThe library names and module names for all the IOF load modules will be listed to the terminal. Be sure that the libraries listed are the correct ones.
|
Note |
The SVC and ESR supplied with IOF is identical for releases
IOF 7D through 8A. The same SVC or ESR can be shared by IOF/TSO
and IOF/CICS. There is no reason to change the IOF SVC or ESR
when upgrading to a newer IOF release.
|
More Help |
Click here to EMAIL a problem report to
IOF Technical Support for additional assistance.
|
Previous | Next |
IOFTech Maintenance Release8G Newsletters Doc FAQ Contact Home
Thursday, 22-Jul-2021 11:38:07 EDT
bsvcesr sfxx nlpa nwhere nsvcesr