High Priority Fixes | |
---|---|
Fix Number
Date |
Problem Description |
C7E1536 26Mar2001 |
An incorrect error message, "OFFSETYF", is raised when overtyping certain fields for NON-HELD datasets on the Job Summary Panel. |
C7E1187 20Mar2001 |
Abend 0C4 on the "L" command when operating in z/OS 64 bit mode. |
C7E1184
11Jan2001 |
In at least one instance a CSA memory overlay has been observed when
a customer installed a new version of JES2 and failed to re-generate
IOF for the new JES2. IOF normally provides an error message when
JES2 mismatches occur, but in this case there was a JES2 control
block change that could not be detected by IOF. This fix prevents
the CSA overlay even if the customer fails to re-generate IOF for
the new JES2 release.
This fix supercedes C7E1160. It should be applied whether or not C7E1160 has already been applied. |
C7E1160
2May2000 |
Replaced by C7E1184 and no longer required. |
U7E1501
15Mar2000 |
A non-authorized user may be permitted to modify the SRVCLASS and QUIESCED fields when operating in GOAL mode. Note that this maintenance is applied to all 7E tapes shipped after March 15,2000. |
Important Fixes Sorted by Date | |
Fix Number
Date |
Problem Description |
C7E1196
10Sept2001 |
Correct IOF to display the Euro character (x'9F') |
U7E1165
26Sept2000 |
Required maintenance to make IOF/7E compatible with OS/390 2.10. This maintenance can be applied prior to converting to 2.10. |
C7E1502 17Mar2000 |
If the B49CMPAT option specified "MVSCHAR=SLASH", entering a command starting with "/" results in error IEE305I. Note that this maintenance is not required unless you specify "MVSCHAR=SLASH" in B49CMPAT. |
Optional Fixes
Please apply only if the description matches your requirement Note that optional fixes are not included in fix zip files |
|
Fix Number | Description of Option |
Optional fix C7E0612 |
If there are no jobs on queue at initial IOF entry, release 7E exits with a NO MATCH error message, instead of jumping to the IOF Option menu as releases 7A and 7B did. This optional fix makes IOF stop at the Option Menu like releases 7A and 7B. |